{"id":45448,"date":"2020-06-02T13:09:44","date_gmt":"2020-06-02T12:09:44","guid":{"rendered":"https:\/\/www.processindustryinformer.com\/product-finder\/product\/import-placeholder-for-44721\/"},"modified":"2025-01-13T14:03:55","modified_gmt":"2025-01-13T14:03:55","slug":"echotel-961-962","status":"publish","type":"product","link":"https:\/\/www.processindustryinformer.com\/product-finder\/product\/echotel-961-962\/","title":{"rendered":"Echotel 961\/962"},"content":{"rendered":"<h2>Echotel\u00ae 961 And 962 Single And Dual Point Ultrasonic Level Switches<\/h2>\n<p>Echotel 961\/962 series are used to detect high or low level alarm(s) in a broad range of liquids. Pulsed signal technology provides superior performance in applications suffering from foam, aeration, heavy turbulence and suspensions containing solids. ECHOTEL 961 has a tip sensitive setpoint and is ideally used as high or<\/p>\n<p>ECHOTEL 961 has a tip sensitive setpoint and is ideally used as high or low-level alarm. ECHOTEL 962 offers 2 setpoints on the same transducer, a tip sensitive setpoint and a second setpoint via a flow-through upper gap. The unit is used for level alarm or to control a pump in an auto fill\/empty mode.<\/p>\n<p>The Enhanced\u00a0Eclipse<sup>\u00ae<\/sup> Model 705 is a 24 VDC loop-powered transmitter based upon the revolutionary guided wave radar (GWR) technology. This single transmitter can be used with all probe types and offers enhanced reliability, as demonstrated by a Safe Failure Fraction of 91%, allowing it to be used in SIL 3 loops.<\/p>\n<p>This ECLIPSE guided wave radar transmitter is designed to provide measurement performance well beyond that of many traditional technologies. The innovative, patented enclosure is a first in the industry orienting both wiring and electronics compartments in the same plane; and, angled to maximize ease of wiring, configuration and data display.<\/p>\n<p>The ECLIPSE Model 705 transmitter supports the FDT\/DTM standard, and a PACT<em>ware<\/em>\u2122 PC software package allows for additional configuration and troubleshooting flexibility.<\/p>\n<p><strong>Operating Principle<\/strong><\/p>\n<p>ECLIPSE guided wave radar is based upon the technology of TDR (time domain reflectometry). TDR utilizes pulses of electromagnetic energy transmitted down a probe. When a pulse reaches a surface that has a higher dielectric than the air\/vapor in which it is traveling, the pulse is reflected. An ultra high-speed timing circuit precisely measures the transit time and provides an accurate level measurement.<\/p>\n<p>ECLIPSE GWR can be utilized to detect overall level or interface level, and when used with a HART\u00ae splitter, it can transmit two 4-20 mA signals.<\/p>\n<p><strong>Applications<\/strong><\/p>\n<ul>\n<li>Petroleum Refining \u2013 Liquefied Gases, Crude Storage, Distillation Columns, Blending Tanks, Finished Product Storage<\/li>\n<li>Power Generation \u2013 Feedwater Heaters, Deaerators, Condensate Tanks, Finished Product Storage<\/li>\n<li>Chemical \u2013 Chemical Injection, Mixing and Blending, Scrubber Vessels, Finished Product Storage<\/li>\n<li>Water &#038; Wastewater \u2013 Clarifier Level, Sludge Level, Lime Slurry Level<\/li>\n<li>Pulp &#038; Paper \u2013 Pulp Storage, Pulp Washing Systems, Bar Screens, Finished Product Storage<\/li>\n<li>Food &#038; Beverage \u2013 Ingredient Storage, Mixing Vessels, Cookers, Finished Product Storage<\/li>\n<li>Pharmaceutical \u2013 Reactors, Buffer Prep, CIP Applications, Finished Product Storage<\/li>\n<\/ul>\n<p><strong>Features<\/strong><\/p>\n<ul>\n<li>Low dielectric measurement capability (\u03b5r >_ 1.4)<\/li>\n<li>Volumetric output<\/li>\n<li>Quick connect\/disconnect probe coupling<\/li>\n<li>Operates in visible vapours and ignores most foams<\/li>\n<li>IS, XP, and Non-Incendive approvals<\/li>\n<li>Ignores coating buildup<\/li>\n<\/ul>\n<p><strong>Options<\/strong><\/p>\n<ul>\n<li>Foundation fieldbus\u2122 or PROFIBUS PA digital outputs<\/li>\n<li>Display\/keypad<\/li>\n<li>Local remote mounting<\/li>\n<li>Interface measurement<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<h2>Echotel\u00ae 961 And 962 Single And Dual Point Ultrasonic Level Switches<\/h2>\n<p>Echotel 961\/962 series are used to detect high or low level alarm(s) in a broad range of liquids. Pulsed signal technology provides superior performance in applications suffering from foam, aeration, heavy turbulence and suspensions containing solids. ECHOTEL 961 has a tip sensitive setpoint and is ideally used as high or<\/p>\n<p>ECHOTEL 961 has a tip sensitive setpoint and is ideally used as high or low-level alarm. ECHOTEL 962 offers 2 setpoints on the same transducer, a tip sensitive setpoint and a second setpoint via a flow-through upper gap. The unit is used for level alarm or to control a pump in an auto fill\/empty mode.<\/p>\n<p>The Enhanced\u00a0Eclipse<sup>\u00ae<\/sup> Model 705 is a 24 VDC loop-powered transmitter based upon the revolutionary guided wave radar (GWR) technology. This single transmitter can be used with all probe types and offers enhanced reliability, as demonstrated by a Safe Failure Fraction of 91%, allowing it to be used in SIL 3 loops.<\/p>\n<p>This ECLIPSE guided wave radar transmitter is designed to provide measurement performance well beyond that of many traditional technologies. The innovative, patented enclosure is a first in the industry orienting both wiring and electronics compartments in the same plane; and, angled to maximize ease of wiring, configuration and data display.<\/p>\n<p>The ECLIPSE Model 705 transmitter supports the FDT\/DTM standard, and a PACT<em>ware<\/em>\u2122 PC software package allows for additional configuration and troubleshooting flexibility.<\/p>\n<p><strong>Operating Principle<\/strong><\/p>\n<p>ECLIPSE guided wave radar is based upon the technology of TDR (time domain reflectometry). TDR utilizes pulses of electromagnetic energy transmitted down a probe. When a pulse reaches a surface that has a higher dielectric than the air\/vapor in which it is traveling, the pulse is reflected. An ultra high-speed timing circuit precisely measures the transit time and provides an accurate level measurement.<\/p>\n<p>ECLIPSE GWR can be utilized to detect overall level or interface level, and when used with a HART\u00ae splitter, it can transmit two 4-20 mA signals.<\/p>\n<p><strong>Applications<\/strong><\/p>\n<ul>\n<li>Petroleum Refining \u2013 Liquefied Gases, Crude Storage, Distillation Columns, Blending Tanks, Finished Product Storage<\/li>\n<li>Power Generation \u2013 Feedwater Heaters, Deaerators, Condensate Tanks, Finished Product Storage<\/li>\n<li>Chemical \u2013 Chemical Injection, Mixing and Blending, Scrubber Vessels, Finished Product Storage<\/li>\n<li>Water &#038; Wastewater \u2013 Clarifier Level, Sludge Level, Lime Slurry Level<\/li>\n<li>Pulp &#038; Paper \u2013 Pulp Storage, Pulp Washing Systems, Bar Screens, Finished Product Storage<\/li>\n<li>Food &#038; Beverage \u2013 Ingredient Storage, Mixing Vessels, Cookers, Finished Product Storage<\/li>\n<li>Pharmaceutical \u2013 Reactors, Buffer Prep, CIP Applications, Finished Product Storage<\/li>\n<\/ul>\n<p><strong>Features<\/strong><\/p>\n<ul>\n<li>Low dielectric measurement capability (\u03b5r >_ 1.4)<\/li>\n<li>Volumetric output<\/li>\n<li>Quick connect\/disconnect probe coupling<\/li>\n<li>Operates in visible vapours and ignores most foams<\/li>\n<li>IS, XP, and Non-Incendive approvals<\/li>\n<li>Ignores coating buildup<\/li>\n<\/ul>\n<p><strong>Options<\/strong><\/p>\n<ul>\n<li>Foundation fieldbus\u2122 or PROFIBUS PA digital outputs<\/li>\n<li>Display\/keypad<\/li>\n<li>Local remote mounting<\/li>\n<li>Interface measurement<\/li>\n<\/ul>\n","protected":false},"featured_media":43768,"template":"","meta":[],"product_brand":[],"product_cat":[68,6291],"product_tag":[],"class_list":{"0":"post-45448","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-process-control-instrumentation","7":"product_cat-ultrasonic-level-switches","9":"first","10":"instock","11":"purchasable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/product\/45448","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/media\/43768"}],"wp:attachment":[{"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/media?parent=45448"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/product_brand?post=45448"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/product_cat?post=45448"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.processindustryinformer.com\/product-finder\/wp-json\/wp\/v2\/product_tag?post=45448"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}