Matt Hale, International Sales & Marketing Director, HRS Heat Exchangers

Maintaining an optimal digester temperature is a key aspect of maximising biogas production and overall process efficiency in anaerobic digestion. Not only is temperature essential to maintain a healthy colony of bacteria, but it can reduce retention times and improve material circulation – thereby helping to increase the production capacity of the whole process.

In terms of temperature regime, anaerobic digestion can be divided into mesophilic or thermophilic systems. Mesophilic digesters are the most common type worldwide, and operate at between 35 °C and 40 °C, typically around 37 °C. In contrast, thermophilic digesters operate at temperatures above 50 °C, with shorter retention times but higher operating energy requirements and are therefore less common.

The methanogenic bacteria in the digester are very sensitive to temperature change, and thermal shocks will reduce the level of methane production. Therefore, it is essential to monitor digester temperature and retain the correct temperature window using heating in order to prevent reduced digester performance. Heating is also required to compensate for heat losses from the digester to the atmosphere and to compensate for the thermal loads which occur when new feedstock is added to the digester.

In some cases, cooling may also be required, for example where the feedstock coming into the digester comes from a higher temperature pre-treatment system such as a pasteuriser or hydrolysis tank. Cooling can also be required in regions with very high ambient temperatures.

Indirect heating (or cooling) based on heat exchangers involves taking sludge from the digester, pumping it through a heat exchanger, and then returning it to the digester at the required temperature. The heat exchanger control system considers variable heat loads from different feedstocks and seasonal changes in ambient temperature.

Maintaining the optimum digestion temperature may require additional heating or cooling

Such an indirect system also has advantages in terms of servicing over older style heating systems which may have a system of pipes in the floor or lower walls of the digestion tank. These systems are being phased out as the pipework is in an aggressive environment so often has a shorter lifespan. It also has the disadvantage that if embedded pipes spring a leak, the digester has to be drained in order to access the pipework, leading to considerable delays and costs.

It is when you consider potential sources of heat that things become most interesting. Obviously generating heat specifically for the purposes of heating the digester is expensive, inefficient, and in some cases will lead to carbon emissions. But in most anaerobic digestion plants there are sources of existing heat which can be utilised, in particular heat from the combined heat and power (CHP) engine, which may otherwise be wasted.

Using a heat exchanger, such as the HRS DTI Series, means that this source of heat can be utilised effectively thanks to their corrugated tube design which reduces fouling and blocking, resulting in long running time with high levels of heat transfer.

Conversely, where cooling is required, it can easily be supplied via a heat exchanger using a medium such as water, and where AD plants are located in regions with wide variations between winter and summer temperature, it may be that both heating and cooling is required. While such a situation will inevitably add complexity to the system design, it is also perfectly feasible to meet such a brief.

So, to return to the question posed in the title, whether you should be heating or cooling your digester – the answer is that it all depends on the actual temperatures you are faced with and the optimum operating temperature of your particular digester. The good news is that whether you need to heat or cool, corrugated tube heat exchangers represent the most energy efficient way to achieve this.

info@uk.hrs-he.com
www.hrs-heatexchangers.com

HRS Heat Exchangers

Recent Posts

A Smarter Way to Monitor Liquid Levels

With advanced video analytics, IVC delivers accurate, real-time measurement without intrusive sensors or costly maintenance.…

2 days ago

Watson-Marlow launches Bredel CIP pump for hygienic, efficient and sustainable cleaning

Watson-Marlow Fluid Technology Solutions (WMFTS), part of the Spirax Group, has announced the launch of…

4 days ago

Optimising Hydraulic Performance: Precision Flow Measurement Challenges

Titan Enterprises shares practical insights to help engineers and operators address the challenges of precision…

6 days ago

Smarter Machines, Stronger Businesses: AI’s Role in the Next Era of Manufacturing

In this episode, we’re exploring the future of real-time process monitoring with a spotlight on…

6 days ago

David Coote and the Death of Privacy: When Work Invades Your Personal Life

The case of former referee David Coote’s out-of-work comments, made towards the end of last…

1 week ago

Why Hazard Studies Fail – and How to Get Them Right

Since being asked to write a column I have been very careful to not drift…

1 week ago