At least 40% of all refrigeration and air conditioning equipment in use in the UK, which includes chillers, operates with R22. With the phase-out deadline for R22 now passed, and an expected shortfall in the availability and price of reclaimed R22, what are the options for facilities managers? Steve Warnock, Managing Director of Coolmation explains.

Time has now run out for existing chillers which use R22 and other HCFC “drop-in’ R22 replacement refrigerants, such as R408 and R409. From 1 January 2010, production of R22 halted, with the EU now indicating a preference to ban recycled R22 by 2012.

Although this phase out was announced and legislated for several years ago through the EU Ozone Regulation, there is little evidence that the necessary steps have been taken to prevent those users of HCFC systems being caught out.

In fact, some R22 users are waiting for a ban on the recycled product to be introduced believing that there will be a readily available supply of reclaimed R22 that they can use until this point.

The signs are that this will be a high risk approach.

Industry sources indicate that the big users of R22 refrigerant, such as pharmaceutical companies, have been steadily stockpiling reclaimed R22, as well as ring-fencing future supplies. Recycled R22 should be available until 2015, but the likely result of this activity is that the amount of recycled R22 becoming available to the general market will fall far short of demand leading to a sharp escalation in its price. In fact, it’s estimated that there will only be enough recycled R22 available to meet an estimated 10-12% of the servicing needs of R22 chillers still in operation. The truth is there will not be enough reclaimed R22 to satisfy demand severely exposing buildings to a major shortfall in their air conditioning.

So where does this leave facilities managers? Well, if you are responsible for the maintenance of a building, which includes maintaining R22 chillers, and you have guaranteed access to a readily available supply of reclaimed R22, then there is no pressing problem. But if you have no reclaimed stocks to rely on what are the options? In our view, there are two choices. Find a replacement refrigerant for the chiller or invest in a new one.

With 1st January 2010 deadline passed it is now illegal to use stockpiled virgin or recovered R22 which hasn’t been reclaimed. To avoid prosecution facilities managers therefore need to act as quickly as possible to ensure they comply with the legislation. One option is refrigerant replacement, which is a quick simple operation that can ensure compliance with minimal disruption. Providing the chiller is in good working order, making a straightforward switch away from R22, will extend its life indefinitely, or at least until it passes the point of economic repair.

The simplest solution and the best opportunity for your client to make the switch from R22 is when the chiller is being repaired, or undergoing a scheduled maintenance. This will eliminate the possibility of disruption at some less convenient time. Certainly, when the chiller is being repaired, it’s highly likely that the R22 refrigerant will have to be removed, and it might not make sense to reinstall R22.

Following developments in alternative refrigerants the replacement of R22 is now a straightforward procedure requiring minimum or no engineering work, and, in most cases, no change of lubricants. Replacement refrigerants, such as MO99, are designed specifically to replace R22 refrigerant in water chillers. MO99 operates very closely to R22’s cooling capacity and energy performance characteristics, showing distinct improvements over other R22 alternatives currently on the market. The release of this refrigerant follows years of laboratory and global field testing offering facilities managers a tried and tested solution to R22 phase out.

Replacing R22 now with this high performance alternative is an immediate cost-effective solution, but looking to the long term, now is the time for facilities managers to start planning their future chiller replacement.

With recent technology developments and improvements in chiller design and performance, replacing old chillers with new high efficiency ones can bring real cost benefits. Replacement can also deliver guaranteed, longer term performance advantages.

However, in a replacement scenario, selecting the most energy efficient chiller is not necessarily that simple, and there is certainly no one ‘silver bullet’ solution for all applications. As a first step, it is necessary to consider each chiller’s EER (Energy Efficiency Ratio), the ratio of cooling output compared to power input.

Eurovent, the European Committee of Air Handling and Refrigeration Equipment Manufacturers, has set its own formulae to calculate EERs, making it easier to compare the performance of chillers manufactured by Eurovent accredited companies. Its classification for full load EER follows a similar path to the A to G approach to the Energy Labelling Directive, with the energy efficiency of chillers designated by Eurovent A or Eurovent B in catalogues and the Eurovent Directory of Certified products.

Yet, a chiller’s EER should not be considered in isolation. Reference to the chiller’s ESEER (European Seasonal Energy Efficiency Ratio), as set out by Eurovent will allow clients to compare the efficiency of one chiller against another under part load conditions, the condition at which most chillers will operate at for most of their working life.

Since the compressor is the single, largest energy consumer within any air conditioning system, the choice of scroll, screw or Turbocor centrifugal chiller is a key factor in defining the EER and ESEER. Chillers featuring the latest oil free Turbocor centrifugal compressors, with their inverter-driven, permanent magnet motor and magnetic bearings, have recently grabbed plenty of headlines. Typically, traditional induction motors of this size are in the 92% efficiency range, but the Turbocor compressor’s permanent magnet DC motor provides an efficiency of between 96 to 97%. Yet, they are not necessarily the best option for all applications.

For those tasks requiring cooling capacities up to 350-400kW, then chillers featuring four or six independently operating scroll compressors are still very likely to be the most efficient selection. Matching a reducing load simply means turning compressors off – considerably more efficient than allowing compressors to continue to run in an unloaded state

For those projects where demand exceeds 500kW, then the choice is probably between a Turbocor or screw chiller. Where load conditions are going to be constantly above 70%, it is probable that a screw compressor chiller will be just as efficient as a Turbocor one, and considerably less expensive. Where loads are likely to reduce for considerable periods to around 50%, Turbocor chillers will be significantly more efficient than screw.

Common sense needs to be applied when selecting chillers by their capacity. The calculated cooling capacity, for example, will very likely include some margin of over capacity. The chiller selected will normally have a slightly higher than lower capacity than the calculated need, and the overall selection will be based on the peak load occurring on the hottest day of the year.  It is also likely that the selection criteria will be based on an ambient condition of up to 35°C. That may be fine for central London, but for more rural or northerly applications is that really necessary? In other words, in no time at all, facilities managers could be committing their clients to an oversized chiller which will cost more to operate and maintain throughout its lifecycle!

In short, for optimum efficiency and reliability, it is better to have a smaller chiller highly loaded than a larger one idling. And with a huge number of installed R22 chillers now requiring either an alternative refrigerant or replacement facilities managers need to seek advice now to ensure they follow the right course of action.

For further information please contact:

Gary Franklin
Chairman
Coolmation Ltd
Unit 7, Millstream Ind Estate
Ringwood
Hampshire, BH24 3SD

Tel:     01425 478971
Fax:     01425 470745
Web:    www.coolmation.co.uk

ABB Drives & Motors

Share
Published by
ABB Drives & Motors

Recent Posts

Bredel CIP pump enhances hygienic processing efficiency

Watson-Marlow Fluid Technology Solutions has launched the Bredel CIP pump, designed to support hygienic and…

3 days ago

A reliable solution for Section 82 compliance

Process instrumentation specialist Endress+Hauser has developed a Continuous River Monitoring Solution to support UK water…

3 days ago

Pump Success Move as Borger UK Accelerates Growth in Shrewsbury

Borger UK, a leading pump manufacturer in the UK, which has firmly established itself as…

3 days ago

AkzoNobel Powder Coatings expands My Interpon Portal with on‑demand services to drive performance speed and sustainability

AkzoNobel Powder Coatings is strengthening support for UK powder coating businesses by expanding the capabilities…

3 days ago

BFM® fitting snap-in connectors installed on flour line to simplify maintenance

The Challenge BakeAway is a UK-based company that has been manufacturing high-quality dough for pastry, pancakes,…

5 days ago

Apex Pumps celebrates award-winning year of growth, investment, innovation and industry recognition

Bristol-based pump manufacturer reports record order book, major investment in UK manufacturing and wins top sustainability honour…

5 days ago