Thermo Fisher Scientific ITQ 700 GC-Ion Trap Mass Spectrometer Offers Enhanced Selectivity and Accuracy in Multi-Residue Pesticide Analysis in Green Tea

Listen to this article

Thermo Fisher Scientific Inc., the world leader in serving science announces another significant gain in laboratory productivity highlighted in a new application note. Combining the low detection levels achievable with the Thermo Scientific ITQ 700 GC-ion trap mass spectrometer with a QuEChERS sample preparation method allows laboratory scientists to greatly enhance sample throughput without sacrificing levels of detection. This milestone is highlighted in the company”s latest application note “Multi-residue Pesticide Analysis in Green Tea by a Modified QuEChERS Extraction and Ion Trap GC/MSn Analysis” which details how to perform accurate, dependable multi-residue pesticide analysis in green tea following sample preparation using the QuEChERS method. The application note is available to download via www.thermo.com/gcfoodsafety

Recently-formulated pesticides are smaller in molecular weight than their predecessors and are designed to break down rapidly in the environment. As a result, to successfully identify and quantify these compounds in foods, more careful consideration must be placed on the sample preparation for extraction and the instrument parameters for analysis. The QuEChERS sample preparation method, published recently as AOAC Method 2007.01, has considerably simplified the determination of pesticides in fruits, vegetable, grains and herbs.

The study was performed by coupling the ITQ 700 with the Thermo Scientific FOCUS GC gas chromatograph in order to determine the linear ranges, quantitation limits and detection limits for a partial list of pesticides that are commonly used on green tea crops. Samples were prepared in matrix using the QuEChERS sample preparation guidelines for analysis by gas chromatography/tandem mass spectrometry (GC/MSn) on the ITQ 700. Caffeine and polyphenols were removed from the samples prior to injection. A Thermo Scientific TRACE TR-Pesticide III 35% diphenyl/65% dimethyl polysiloxane column was chosen to improve the resolution of the more polar compounds.

A single splitless injection of 22 pesticides was performed with detection in electron ionization (EI) MS/MS. Multiple matrix spikes were analyzed at both high and low levels to verify the precision of the analytical method.
The MS/MS scan mode offered significantly enhanced selectivity over scanning modes such as full scan and selected ion monitoring (SIM). The ITQ 700, operated in the MS/MS mode, generated unique product ion spectra by collision-induced fragmentation of each of the detected pesticides. Because of the highly effective elimination of matrix interfering ions, more accurate results were produced at the lower levels.

For more information about the Thermo Scientific GC/MS food safety applications, please call +1 866-463-6522, e-mail analyze@thermofisher.com or visit www.thermo.com/gcfoodsafety

 

Phil Black - PII Editor

I'm the Editor here at Process Industry Informer, where I have worked for the past 17 years. Please feel free to join in with the conversation, or register for our weekly E-newsletter and bi-monthly magazine here: https://www.processindustryinformer.com/magazine-registration. I look forward to hearing from you!

Share
Published by
Phil Black - PII Editor

Recent Posts

5 of the Best Palletizers for Large-Scale Production

End-of-line palletizing can become a factory’s biggest bottleneck. On busy production floors, slow case stacking…

1 hour ago

Essentra launches new PEEK fastener range with exceptional thermal stability and mechanical properties

Essentra Components, a leading supplier of essential industrial parts and fastening solutions, has announced the…

1 hour ago

Great North Run for New Landia Chopper Pumps

One of the leading water companies in the North of England installed three new robust…

4 days ago

Multistage Muscle: Driving Diesel Transfer with Precision

North Ridge Pumps recently delivered four heavy-duty horizontal multistage pumps to meet diesel transfer operations…

4 days ago

Interpon Colour of the Year 2026 Attracts Blues for Balance, Reconnection

AkzoNobel has unveiled its Interpon 2026 Colour of the Year, unveiling not one but three…

5 days ago

Comparing Multifunction and Single-Function Process Calibrators

Accuracy of measurement is important in the process industry. Everyday, thousands of calibrations are conducted…