Wafer-Cone Flow Meter Is Now Available With CE Marking For All Service Categories Under European Pressure Equipment Directive (PED)

Listen to this article

Ideal for Small Line Size Liquid, Gas or Steam Measurement in Oil/Gas Production,
District Energy, Food & Beverage, Metal and Mining, Chemical Refining, Pharmaceuticals, Electric Power Generation, Water Treatment

To support McCrometer’s European customers, the high-accuracy, virtually no-maintenance Wafer-Cone® Flow Meter meets the requirements of the European Community’s Pressure Equipment Directive (PED) 97/23/EC and is  eligible for use throughout the region.

The PED standard was adopted by the European Parliament and the European Council in1997. It provides standards for the design, manufacture, testing and the uniform assessment of equipment and assembliesoperating in pressurized environments across the European Community.

CE Marking for all service categories under the Pressure Equipment directive (PED) 97/23/EC means that McCrometer’s European customers have third party assurance that the Wafer-Cone Flow Meter is safe for use in the pressurized environments found in industrial processes and plants.  The Wafer-Cone Flow Meter meets essential safety requirements covering design, manufacture and testing; satisfies appropriate conformity assessment procedures; and carries the CE marking and other information.      

The Wafer-Cone Flow Meter is ideal for liquid, gas or steam service in line sizes from 1 to 6 inches. The meter’s flangeless design makes installation easy, while the interchangeable cone offers flexibility to accommodate changing flow conditions without recalibration. When flow conditions change over time, the cone can be removed and replacedwith a cone at a different beta ratio eliminating the need to buy a new meter.

Space-saving and field-proven, the Wafer-Cone Flow Meter can be installed virtually anywhere in a piping system or be easily retrofit into an existing piping layout. No moving parts, virtually no maintenance and an economical cost make it ideal for applications including: wellheads, gas, CO2 and water injection, gas lift, compressor anti-surge, fuel gas, separator discharge, biogas reactors, cooling systems, plant HVAC, process gas lines and more.

The Wafer-Cone Flow Meter’s unique differential pressure sensing technology with built-in flow conditioning greatly reduces the required straight pipe run for installation as comparedwith technologies such as orifice plates and Venturi meters. The Wafer-Conemeter is highly accurate and requires of straight run of only 1-3 pipe diameters upstream and 0-1 pipe diameters downstream to ensure measurement reliability. Its ability to self-condition flow makes it a space-saver, allowing for a reduction of the instrument overall footprint and weight.

The Wafer Cone Flow Meter’s built in flow conditioning and resulting stable flow profile achieve an accuracy of +1.0 percent, with a repeatability of +0.1 percent, and operates over a flow range of 10:1.  The Wafer Cone Flow Meter raises the bar for economy, ease of use and performance.

The Wafer-Cone‘s design features a centrally-located cone inside a tube, which interacts with the fluid flow and reshapes the velocity profile to create a lower pressure region immediatelydownstream.  The pressure difference exhibited between the static line pressure and the low pressure created downstream of the cone can be measured via two pressure sensing taps.  One tap is placed slightly upstream of the cone and the other is located downstream of the cone.  The pressure difference can then be incorporated into a derivation of the Bernoulli equation to determine the fluid flow rate.

The Wafer-Cone’s direct mount configuration minimizes installation labor while ensuring accuracy. Direct mounting the transmitter eliminates impulse lines, which lowers installation costs and reduces potential leak points by more than 50 percent. Simple plug-and-play mounting ensures the meter is installed correctly and eliminates a potential source of flow measurement errors.

Company Contact: Jennifer Kerckhoff
Company Address: 3255 W Stetson Ave, Hemet, CA 92545
Web: http://www.mccrometer.com
Tel: 800-220-2279 Tel: 951-652-6811 Fax:  951-652-3078

Phil Black - PII Editor

I'm the Editor here at Process Industry Informer, where I have worked for the past 17 years. Please feel free to join in with the conversation, or register for our weekly E-newsletter and bi-monthly magazine here: https://www.processindustryinformer.com/magazine-registration. I look forward to hearing from you!

Share
Published by
Phil Black - PII Editor

Recent Posts

Driving Change: How Hyper-Efficient Motors Are Reshaping Industries

Beamex is your trusted partner for calibration excellence, providing accurate measurements, reliable data, and traceability…

8 hours ago

Why Chemical Firms Are Reducing Toxic Substances

Chemical giants are shedding light on why cutting down on toxic substances is now a…

1 day ago

How AI Is Transforming the Factory Floor

Andrew Sherlock, Director of Data-Driven Manufacturing, National Manufacturing Institute Scotland (NMIS) Artificial intelligence (AI) is…

1 day ago

IChemE Launches Inquiry into UK Chemical Engineering Research

The Institution of Chemical Engineers (IChemE) has announced a significant presidential inquiry into the current…

3 days ago

UK REACH ATRm Progress Met With Caution by Chemical Industry

A Multidisciplinary Approach This research combined numerical analysis with hands-on experimentation. By employing high-speed photography…

3 days ago

Research Finds Cast Iron Water Pipes Can Temporarily Reseal

Recent research has uncovered some exciting news about cast iron pipes—they can actually 'reseal' themselves,…

3 days ago