The latest issue off PII is out now!

Read here!
Fluids Handling

Watson-Marlow Tube Pump Aids Hunt For Harmful Microplastics

Listen to this article

A research project looking at the problem of microplastics in inland waters has been using a 323Dz tube pump from Watson-Marlow Fluid Technology Group (WMFTG) to ensure sampling is practical, reliable and consistent. The compact 300 series pump not only operates with the required accuracy and reliability, but eliminates the potential for plastic contaminants to cause inaccurate measurement results. Sampling is performed automatically at programmed intervals.

Although shocking images have highlighted the problem of plastic waste in oceans, the issue of microplastics in inland waters has gone relatively unnoticed. However, increasing quantities of plastic particles that are 5mm or less in size are now commonplace in lakes and rivers. Private households are among the main culprits, mainly due to particles detaching from textiles during washing cycles. Particles from cosmetics are also problematic.

The PLASTRAT research project, co-ordinated by Bundeswehr University Munich and supported by the German Federal Ministry of Education and Research (BMBF), aims to assess the size and scale of the problem.

The challenges of sampling

One of the initial primary tasks of PLASTRAT was to develop a uniform, comparable method for taking samples at wastewater treatment plants“, explains Univ.-Prof. Dr Christian Schaum, Professor for Sanitary Engineering and Waste Management at Bundeswehr University Munich. Samples must be taken at timed intervals to compensate for fluctuations throughout the day and ensure proper comparisons. The procedure must also exclude the potential for samples to become contaminated by other plastic particles.

Working at the Fellach wastewater treatment plant in Holzkirchen, near Munich, researchers developed a sampling procedure that takes these criteria into consideration. Over 24 hours, a pump feeds the water from which samples are to be taken into a holding tank. The water in this 1,000 litre tank is then stirred to promote homogenisation and create a mixed sample.

The sample is subsequently passed through a multi-level cascade of filters with pore sizes of 50 and 500 μm to concentrate the microplastic particles,” explains Natalie Wick, a member of the project team. “The filtration residues are analysed to see how much microplastic remains.

One pump meets many requirements

One of challenges when developing this procedure was selecting the optimum pump for sampling.

Samples had to be taken at the sand trap outlet, as well as the outlet from the secondary treatment area, at different wastewater treatment plants,” explains Ms Wick. “Therefore, the pump had to be light and versatile, but also robust and reliable.”

Alongside high levels of precision, the sample water sometimes had to be pumped into tanks that were several metres higher than the water level. Furthermore, the pump would need programmable interval dispensing functions and be able to draw in water autonomously. However, the most important requirement arose from the very nature of the research subject.

As we wanted to investigate the presence of plastic particles in the water, it was important that the samples were not contaminated with other plastic,” says Ms Wick.

To exclude this possibility, the only plastics which could be used were silicone or Teflon. These materials were not found in any significant quantities in the wastewater samples and could therefore be excluded from the analysis process.

No blockages or contamination

It quickly became clear that only a tube pump could satisfy this long list of requirements. Thanks to its closed peristaltic pumping system, only the tube comes into contact with the medium, in this case the water sample. Unlike other pump types, such as those based on centrifugal or diaphragm technologies, a tube pump has no impellers, seals or valves in the area through which the medium is fed. This design not only prevents contamination,

Tube pumps are the best solution for continuous autonomous sampling at intervals over 24 hours because they are self-priming and effectively prevent damage that would be caused by running dry. Moreover, powerful suction handles any difference in height between the point at which the sample is taken and the holding tank.

Precise, programmable and easy to use

We've already had positive experiences with Watson-Marlow tube pumps in our laboratories,” reports Professor Schaum. These successful encounters led to the selection of a Watson-Marlow 300 series cased tube pump, which would subsequently be used to feed 1,000 litres of water into the sample tank over 24 hours. The pump extracts 5 litres of water in each of the 200 sampling cycles, with automatic transportation taking approximately 2.5 minutes. The pump can be easily programmed to perform a set number of dispensing processes with a specific quantity at set time intervals.

Thanks to the flip-top pumphead, the tube, or even the entire pumphead, can be swapped out in a matter of minutes. In this project, a silicone tube supplied by Watson-Marlow was used to prevent samples from being contaminated by plastic particles. As the pump and the tube were manufactured by the same company, they were perfectly compatible and able to reliably achieve the necessary sampling accuracy.

The Watson-Marlow 300 series tube pump has already been running for more than two years and “works reliably and efficiently when taking numerous samples in very many different situations”, concludes Ms Wick.

www.wmftg.com

Watson Marlow
Premium Package

Watson-Marlow Fluid Technology Solutions

About us

Watson-Marlow Fluid Technology Group (WMFTG) peristaltic tube and hose pumps meet requirements including: value for money; low cost of ownership; reliability and ease of maintenance to the food and beverage, chemical, pharmaceutical, mining and many other industries.

We demonstrate how pumps deliver significant process efficiencies over the lifetime of the equipment. Whether performing flavouring addition in food processing, chemical metering in water treatment or mineral recovery, we have a solution which can cut pump downtime and reduce costs through higher accuracy metering and transfer. WMFTG has dedicated application engineers available to help customers make the right pump and tubing choice from a range providing microlitres per minute to 80 cubic metres per hour flow rates.

The only part of the pump to come into contact with the product is the tube or hose. This means there are no seals or valves that can wear or fail. Replacing the tube or hose can be performed quickly and safely. Peristaltic pump benefits include:

Total fluid containment with no seals No ancillaries Handle viscous and abrasive slurries and sludge Self-priming capability Dry running without damage to the pump In addition to their range of positive displacement pumps, Watson-Marlow Fluid Technology Group has added PTFE-lined chemical and industrial hoses to their range. Aflex hoses are reinforced to withstand the most severe conditions and use.

Where we supply to

Europe, Africa, Asia, Australia, South America, North America

Industries we supply to

Automation, Chemicals, Consultants, Components Electronics, Energy and Power, Food and Beverage, Glass Ceramics Cement, Metals and Minerals, OEM, Paper and Pulp, Pharmaceutical Cosmetics Toiletries, Plastics and Rubber, Recycling, Textiles, Tobacco, Water and Wastewater

  • Flexicon PF7 tabletop peristaltic liquid filling machine

  • Sterile ReNu SU Technology cartridge

  • Quantum and ReNu SU Technology cartridge - Make sterile connections in non-sterile environments

Show More

    Would you like further information about this article?

    Add your details below and we'll be in touch ASAP!


    Input this code: captcha

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Back to top button

    Join 25,000 process industry specialists and subscribe to:

    PII has a global network of suppliers ready to help...