Editorial ArchiveFluids HandlingFluids Handling

Pumping Strategies for Handling ShearSensitive Fluids

By Russell Morgan, Managing Director of Flux Pumps U

Listen to this article
Russell Morgan - p
Pumping shear-sensitive fluids expert

Pumping shearsensitive fluids presents a unique challenge. Their molecular structure and rheology can be compromised by excessive mechanical stress during transfer. Whether dealing with emulsions, biological suspensions, polymer solutions, food ingredients, or cosmetic formulations, using the wrong pump can lead to product degradation, unexpected viscosity changes, aeration, separation or irreversible structural breakdown.

Understanding how pump design and performance characteristics influence shear sensitive liquids is essential for maintaining product integrity. This article outlines key strategies for safely transferring shearsensitive media from drums and containers, drawing on established engineering principles and practical experience from industrial fluidhandling applications.

Understanding Shear Sensitivity in Industrial Fluids

Shearsensitive fluids respond negatively to high velocity gradients. When exposed to excessive shear through use of incompatible pumps, products may:

  • Reduce in viscosity or even thicken unpredictably
  • Separate (eg. emulsions, dispersions)
  • Experience cell rupture (biological media)
  • Become entrained with gas bubbles
  • Suffer from excessive foaming
  • Sustain irreversible structural damage

How Shear Rate Affects Fluid Viscosity and Product Quality

Shear rate describes how quickly adjacent layers of a fluid move relative to one another and is typically expressed in reciprocal seconds (s⁻¹). It is an important consideration when pumping non-Newtonian fluids, whose viscosity can change depending on the amount of shear applied.

For example, shear-thinning fluids become less viscous as shear rate increases, while shear-thickening fluids become more resistant to flow. Some materials are also thixotropic, meaning their viscosity decreases under sustained shear and gradually recovers when left at rest.

For products such as emulsions, polymer solutions and biological suspensions, excessive shear can cause changes that affect stability, texture, consistency or product performance. Understanding the fluid’s rheological properties is therefore essential when determining the appropriate pump type, operating speed and transfer conditions.

The challenge is to move these fluids efficiently while minimising mechanical stress. Pump selection and associated component geometry plays a central role, but so do operating conditions and pipework system layout.

pumping shear-sensitive fluids

Best Pumping Strategies for Handling Shear-Sensitive Fluids

1. Choose Low-Shear Positive Displacement Pumps

The challenge is to move these fluids efficiently while minimising mechanical stress.

Positive displacement pumps, particularly progressive cavity, lobe, peristaltic and diaphragm designs, are the preferred choice for shearsensitive fluids. Their low internal velocities and gentle transfer characteristics reduce stress on the product. These pumps transfer a fixed volume of fluid per rotation (or cycle), with flow rate proportional to speed, while maintaining constant discharge pressure.

Centrifugal pumps should generally be avoided. Highspeed impellers generate steep velocity gradients, making them unsuitable for delicate emulsions or biological suspensions. Furthermore, they cannot handle high viscosity fluids and will simply cavitate with slow-flowing media.

Low-Shear Positive Displacement Pumps
progressive cavity pumps group

2. Control Pump Speed and Torque Delivery

Shear increases with rotational speed. Operating pumps at lower RPM reduces turbulence and internal friction, while allowing time for viscous media to flow into the pump inlet. Variablespeed drives allow operators to tune performance to protect the fluid’s rheology.

Torque control is equally important. Sudden torque changes can cause microshear events within the fluid. Smooth acceleration and deceleration profiles help maintain product consistency.

3. Optimise Pump Geometry and Internal Clearances

Internal pump components directly influence shear. Positive displacement pumps generally have high clearances and smooth flow paths to reduce velocity gradients.

Progressive cavity pumps are widely used in food, cosmetics and pharmaceutical production, as not only do they minimise shear, they have few moving parts and are also extremely easy to dismantle and clean.

vaseline pump application
tomato paste viscoflux mobile pump application

4. Design Pipework to Reduce Turbulence and Pressure Losses

System layout matters. Sharp bends, restrictions, valves and abrupt pipe diameter changes create turbulence and high shear zones. Designing pipework with gentle transitions and consistent diameter reduces stress on the fluid.

Laminar flow should be the goal wherever possible. Even the best pump cannot compensate for a system that induces turbulence downstream.

5. Maintain Stable Fluid Temperature During Pumping

Many shearsensitive fluids are also temperaturesensitive. Shear can generate heat, and heat can accelerate degradation. Pumps with efficient hydraulic design reduce energy losses and minimise temperature rise.

Monitoring temperatures during transfer is essential when handling delicate biological media, polymer solutions, and heatsensitive emulsions.

vaseline pumping application

6. Prevent Pump Cavitation and Maintain Adequate NPSH

Cavitation introduces extreme shear forces on the liquid and can destroy delicate structures within seconds. Cavitation occurs when liquid pressure at the pump inlet drops below the vapour pressure of the fluid. It results in creation of vapour bubbles which forcibly collapse as pressure increases inside the pump. Ensuring adequate NPSH, avoiding suction lift and maintaining stable pump inlet conditions are critical. Moreover, cavitation introduces additional heat into the product.

Thanks to their suction characteristics, progressive cavity pumps are less prone to cavitation than centrifugal designs. Plus a significant benefit of using vertical progressive cavity pumps to empty vessels, drums or IBC’s, is that the pump inlet is fully immersed in the media. This eliminates suction lift requirements and atmospheric pressure also helps push product into the pump inlet. Finally, these pumps can be specified with soft stator materials, eg. FKM or NBR, that will also dampen any effects of cavitation.

Types of Pumps for Shear-Sensitive Fluids

Several pump technologies are suitable for handling shear-sensitive liquids, although their suitability depends on the fluid’s viscosity, sensitivity to mechanical stress, solids content and required transfer rate. Positive displacement pumps are frequently selected because they move fluid through controlled chambers or cavities rather than relying on high-speed impeller action.

Progressive Cavity Pumps for Gentle Fluid Transfer

Progressive cavity pumps use a rotating helical rotor within an elastomeric or metallic stator to move fluid through a series of sealed cavities. Their steady, low-pulsation delivery and ability to handle viscous media make them suitable for applications involving polymers, emulsions, food ingredients and other shear-sensitive products. Operating speed and rotor-stator selection are important considerations when protecting product integrity.

Rotary Lobe Pumps for Shear-Sensitive Products

Rotary lobe pumps use rotating lobes to transfer fluid through the pump casing with relatively low pulsation. Their design can accommodate viscous products and suspended solids while providing gentle handling when correctly specified and operated. They are commonly used in food processing, cosmetics and pharmaceutical applications where product quality and hygiene are important.

Peristaltic Pumps for Delicate and Viscous Fluids

Peristaltic pumps transfer liquids by compressing a flexible hose or tube, creating a travelling action that moves the product towards the discharge. As the fluid only contacts the inside of the hose or tube, this design can be useful for sensitive, abrasive or contamination-sensitive applications. Pump speed and hose selection remain important factors in determining suitability.

Diaphragm Pumps for Sensitive Fluid Applications

Even the best pump cannot compensate for a system that induces turbulence downstream.

Diaphragm pumps use a flexible membrane to displace fluid through a chamber, providing a pumping action without a rotating impeller in the product stream. They can be suitable for delicate fluids, slurries and products containing suspended solids. Air-operated diaphragm pumps can also provide variable flow control, although their pulsating delivery and operating characteristics need to be considered.

The most appropriate design will depend on the characteristics of the product and the operating conditions of the application.

How to Select the Right Pump for Shear-Sensitive Fluids

Choosing the correct pump requires evaluation of:

  • Fluid rheology (viscosity, thixotropy, yield stress)
  • Sensitivity to mechanical stress
  • Required flow rate and discharge pressure
  • Temperature limits
  • Chemical compatibility
  • Hygiene or cleaning requirements
viscopower set roter motor fmo grosser flansch fs for pumping shear-sensitive fluids

It’s unlikely a single pump will suit all shearsensitive fluids. The best solution often involves balancing lowshear performance with process efficiency and desired flow rate.

Pump Trials and Testing for Shear-Sensitive Applications

The best way to check performance and product integrity when pumping high viscosity, shear-sensitive media is to carry out a trial. Flux Pumps UK regularly advises manufacturers on pump selection for shearsensitive media. This includes applications in food processing, cosmetics, pharmaceuticals and speciality chemicals.

Protecting Product Integrity Through Smart Pumping Strategies

Shearsensitive fluids demand careful handling. By selecting the right pump with optimised component geometry, controlling rotor speed and designing pipework systems that minimise turbulence, process engineers can protect product quality and reduce waste.

For engineers seeking deeper guidance on pump fundamentals, technical resources are available at Flux Pumps UK. 


FAQs: Pumping Shear-Sensitive Fluids

What are shear-sensitive fluids?

Shear-sensitive fluids are liquids whose physical properties or internal structure can change when subjected to mechanical forces during pumping, mixing or processing. Examples include emulsions, polymer solutions, biological suspensions, food ingredients and cosmetic formulations. Excessive shear can alter viscosity, cause separation or damage delicate structures.

What is the best pump for shear-sensitive fluids?

The most suitable pump depends on the fluid’s viscosity, rheological properties and sensitivity to mechanical stress. Progressive cavity, rotary lobe, peristaltic and diaphragm pumps are commonly considered for low-shear applications. Pump speed, internal geometry and operating conditions must also be taken into account.

Why are progressive cavity pumps suitable for shear-sensitive liquids?

Progressive cavity pumps transfer fluid through a series of cavities formed between a rotating helical rotor and a stator. This provides a steady, low-pulsation pumping action that can reduce mechanical stress on sensitive products. They are particularly useful for viscous fluids, polymers, emulsions and products containing suspended solids.

Can centrifugal pumps handle shear-sensitive fluids?

Some centrifugal pumps can handle certain shear-sensitive fluids, but their high-speed impeller action can create significant velocity gradients and turbulence. Their suitability depends on the product’s sensitivity, pump design and operating speed. Positive displacement pumps are often preferred where maintaining product structure is particularly important.

How does pump speed affect shear-sensitive fluids?

Pump speed influences the shear rate experienced by a fluid as it passes through the pumping mechanism. Higher speeds can increase mechanical stress, turbulence and heat generation. Operating at an appropriately lower speed can help protect sensitive products, although the optimum setting depends on pump design and fluid properties.

What is shear rate in fluid pumping?

Shear rate describes the velocity difference between adjacent layers of a moving fluid and is typically measured in reciprocal seconds (s⁻¹). It is an important consideration when pumping non-Newtonian liquids because their apparent viscosity can change depending on the shear rate applied.

What is the difference between shear-thinning and shear-thickening fluids?

Shear-thinning fluids become less viscous as shear rate increases, making them easier to move under certain pumping conditions. Shear-thickening fluids behave in the opposite way, becoming more viscous as shear increases. Understanding these properties helps engineers select suitable pumps and operating conditions.

How can cavitation damage shear-sensitive fluids?

Cavitation occurs when local liquid pressure falls below the fluid’s vapour pressure, causing vapour bubbles to form and subsequently collapse as pressure increases. This can create localised shock waves, noise, vibration and mechanical damage. In sensitive products, these effects may also damage internal structures or affect product consistency.

How can pipework design reduce shear during pumping?

Pipework should be designed to minimise unnecessary turbulence and pressure losses. Smooth transitions, appropriately sized pipework, gentle bends and fewer restrictions can help reduce excessive velocity gradients and mechanical stress during fluid transfer.

Which industries use low-shear pumping systems?

Low-shear pumping systems are used in food and beverage processing, pharmaceutical manufacturing, cosmetics, biotechnology, speciality chemicals and water treatment. Applications include transferring emulsions, creams, polymer solutions, biological suspensions and other products where maintaining fluid properties is important.

How do you select a pump for high-viscosity and shear-sensitive fluids?

Pump selection should consider viscosity across the expected operating temperature and shear-rate range, fluid composition, required flow rate, discharge pressure, suction conditions, chemical compatibility and product sensitivity. Application trials and consultation with the pump manufacturer can help establish the most appropriate design and operating parameters.

Show More

    Would you like further information about this article?

    Add your details below and we'll be in touch ASAP!


    Input this code: captcha

    russellmorgan

    Russell is Director of Flux Pumps UK, a leading supplier of drum pumps, container pumps and fluid handling solutions. Drawing on his technical knowledge and practical industry experience, he provides expert guidance on pump selection, process efficiency and solving complex fluid transfer challenges across multiple industries.
    Back to top button

    Join 25,000 process industry specialists and subscribe to:

    PII has a global network of suppliers ready to help...