Maintaining an optimal digester temperature is a key aspect of maximising biogas production and overall process efficiency in anaerobic digestion. Not only is temperature essential to maintain a healthy colony of bacteria, but it can reduce retention times and improve material circulation – thereby helping to increase the production capacity of the whole process.

In terms of temperature regime, anaerobic digestion can be divided into mesophilic or thermophilic systems. Mesophilic digesters are the most common type worldwide, and operate at between 35 °C and 40 °C, typically around 37 °C. In contrast, thermophilic digesters operate at temperatures above 50 °C, with shorter retention times but higher operating energy requirements and are therefore less common.

The methanogenic bacteria in the digester are very sensitive to temperature change, and thermal shocks will reduce the level of methane production. Therefore, it is essential to monitor digester temperature and retain the correct temperature window using heating in order to prevent reduced digester performance. Heating is also required to compensate for heat losses from the digester to the atmosphere and to compensate for the thermal loads which occur when new feedstock is added to the digester.

In some cases, cooling may also be required, for example where the feedstock coming into the digester comes from a higher temperature pre-treatment system such as a pasteuriser or hydrolysis tank. Cooling can also be required in regions with very high ambient temperatures.

Indirect heating (or cooling) based on heat exchangers involves taking sludge from the digester, pumping it through a heat exchanger, and then returning it to the digester at the required temperature. The heat exchanger control system considers variable heat loads from different feedstocks and seasonal changes in ambient temperature.

maintaining optimum digestion temperature
Maintaining the optimum digestion temperature may require additional heating or cooling

Such an indirect system also has advantages in terms of servicing over older style heating systems which may have a system of pipes in the floor or lower walls of the digestion tank. These systems are being phased out as the pipework is in an aggressive environment so often has a shorter lifespan. It also has the disadvantage that if embedded pipes spring a leak, the digester has to be drained in order to access the pipework, leading to considerable delays and costs.

It is when you consider potential sources of heat that things become most interesting. Obviously generating heat specifically for the purposes of heating the digester is expensive, inefficient, and in some cases will lead to carbon emissions. But in most anaerobic digestion plants there are sources of existing heat which can be utilised, in particular heat from the combined heat and power (CHP) engine, which may otherwise be wasted.

Using a heat exchanger, such as the HRS DTI Series, means that this source of heat can be utilised effectively thanks to their corrugated tube design which reduces fouling and blocking, resulting in long running time with high levels of heat transfer.

Conversely, where cooling is required, it can easily be supplied via a heat exchanger using a medium such as water, and where AD plants are located in regions with wide variations between winter and summer temperature, it may be that both heating and cooling is required. While such a situation will inevitably add complexity to the system design, it is also perfectly feasible to meet such a brief.

So, to return to the question posed in the title, whether you should be heating or cooling your digester – the answer is that it all depends on the actual temperatures you are faced with and the optimum operating temperature of your particular digester. The good news is that whether you need to heat or cool, corrugated tube heat exchangers represent the most energy efficient way to achieve this.

info@uk.hrs-he.com
www.hrs-heatexchangers.com

HRS Heat Exchangers

HRS Heat Exchangers

About us

HRS Heat Exchangers operates at the forefront of thermal technology, offering innovative and effective heat transfer products worldwide, focusing on managing energy efficiently. Providing a range of heat exchangers, modules and complete processing systems that help you to optimise production, make the most of raw materials, whilst reducing energy consumption, waste and emissions. With 40 years’ experience specialising in design and manufacture of an extensive range of turnkey systems and components incorporating our corrugated tube and scraped surface heat exchanger technology, in compliance with the Global Standards. HRS has a global network of offices: UK, Spain, USA, Malaysia, Australia, India, Russia and Mexico; with manufacturing plants in the UK, India and Spain. Our patented and proven heat transfer technologies, combined with our knowledge make it possible to offer best in class solutions for a wide range of industries and applications.

What we do in a nutshell

HRS Heat Exchangers operates at the forefront of thermal technology, offering innovative and effective heat transfer products worldwide, focusing on managing energy efficiently.

Where we supply to

UK Ireland, Europe, Asia, Australia, South America, North America

Show More

    Would you like further information about this article?

    Add your details below and we'll be in touch ASAP!


    Input this code: captcha

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Back to top button

    Join 25,000 process industry specialists and subscribe to:

    PII has a global network of suppliers ready to help...