From adding oxygen to the wort in a brewery, to introducing the chemical array in a clean in place (CIP) process, optimising dosing accuracy and repeatability is vital. To achieve these aims, a mass flow meter and control valve combination will increase process quality and efficiency. However, it’s also important to ensure optimal integration and specification within the process infrastructure to achieve the best performance and control across a water treatment application.

Greg Wainhouse, Industry Account Manager for Water Applications at Bürkert, explains the importance of selecting the right design and specification for an installation to ensure process optimisation.

Across all chemical or gas dosing requirements for water treatment processes, technology specification is vital for accurate measurement and control. Prior to selecting the flow metering and control hardware, the first step is to ensure that the pipework is optimised for the application. Process application engineers commonly oversize pipework with the goal of reducing pressure drops across the system, as well as offering the flexibility of upscaling capacity at a later date. However, oversized pipe diameters and inappropriate configurations can cause inaccuracies that impact the quality of the process as a whole.

Burkert mass flow meter control valve

Pipe diameter and low accuracy metering

Flow measurement of liquids & gases is essential for determining the volumes of additive that need to be dispensed; maintaining accurate flow readings is important for the whole process. However, an oversized pipe typically means low velocity flow, which generally causes inaccuracies in flow measurement, because it creates an uneven or transitional flow profile characteristic across the sensor.

This creates a fluctuating flow reading that causes a corresponding variable output, with a knock-on effect to additional equipment such as pumps and valves. In liquid flow applications, 1m/sec is generally the optimal “out of the box” factory-calibrated flow velocity for most flow measuring technologies, because of its stable flow profile for reliable measurement. Even for entry-level budget devices right through to more complex advanced flow measuring technologies, manufacturers will usually state that accuracy is improved when measurement is taken at around 1m/sec.

For designers and engineers, this increase in velocity can often be achieved just by reducing the pipe diameter. Even a single standardised line size reduction can have a big impact on improving the accuracy of flow sensor measurement. However, if the existing line size is maintained, users risk velocities that are lower than the minimum capability of the measurement technology.

Oversizing the pipe will also increase the wear on a valve, particularly its seals, through the hunting effect. A fluctuating input means that the control valve opens and closes at a frequent and uncontrolled rate in an attempt to identify the correct position and maintain the target flow point. This can also impact pump operation, leading to a similar acceleration in lifetime wear, increasing costs in maintenance, hardware and through downtime.

The position of the flow meter within the system is also crucial to ensure accurate readings. Bends in pipework in close proximity to the sensor, as well as obstructions, such as additional components, can also cause turbulent, slow or uneven flow characteristics such as eddies. These factors can create the same challenges as an oversized pipe.

In gas applications, changes in velocities before the metering system will impact on the measurement stability. This will create an unstable flow profile that is not representative of factory-calibrated conditions.

Operators and commissioning engineers can often dampen a sensor’s output in an attempt to stabilise the control loop, but this is only masking the accuracy issue. The process will not be as accurate as designing and installing the optimal line size or location and these factors should be addressed at outset.

Modulating control for better accuracy

Adding a modulating control valve to the system can also help to increase dosing accuracy. Controlling pressure and/or flow, a control valve provides responsive control that improves the accuracy and repeatability of the process. It provides precise control trimming and can also regulate multiple channels from a single source.

Ideally, a control valve establishes a linear increase between the Kv value, the amount of flow at a given valve position with a pressure loss of 1 bar, to stroke opening. This control curve ratio changes based on the type of control valve used, as well as the position of the designed valve. The flow control partner will be able to specify the ideal technology, as well as assist in accurately sizing the valve, including calculation of the inlet and changing outlet pressures. Dynamic, multipoint performance data can help to specify an accurate and predictable valve, optimised for the application’s characteristics and requirements.

Burkert mass flow meter control valve
An example of a dosing control module

Improved control at lower cost

Increased application accuracy and repeatability will not only improve process performance and end-product quality, but it can also help to reduce process costs by optimising the volume of the chemical being dosed. Improvement in metering and control typically means using a lower volume of chemicals with no loss in quality.

In a recent example, a Bürkert customer involved in wastewater treatment had inadequate monitoring over sludge thickness that caused fluctuations in the polymers introduced for the dewatering process. This resulted in excessive chemical use and poor sludge thickness from the process. Introducing a mass flow meter and control valve could have enabled close correlation between sludge level and polymer dosing, reducing process costs in raw materials.

Reliable integration

While combining sizing techniques and technology specification can improve process optimisation, integrating the required technologies is also important to ensure reliability. An integrated flow control portfolio enables repeatable performance, communications compatibility and ultimately, ensures system uptime and throughput.

Bürkert is ideally positioned to achieve these requirements to optimise existing as well as new water treatment processes.

Kirsty Anderson
Bürkert Fluid Control Systems
Tel: +44 (0)1285 648761  Fax: +44 (0)1285 648721
Web: www.burkert.co.uk
Email: kirsty.anderson@burkert.com

Burkert
Advance Package

Burkert Fluid Control Systems

burkert-about-us

About us

Bürkert is present in thirtyfive countries around the world. We also work with a large network of distributors and partners, which means we are as close as possible to our customers. This global presence ensures full service and support to all of our customers in every country around the world. Research is the lifeblood of our company.

At Bürkert, we are never satisfied with the status quo and are continually seeking new technologies and solutions for our customers. Every year, our people develop new and highly advanced products and solutions, ranging from integrated process measurement and control units to the most sophisticated systems used in pharmaceutical research. To be a market leader, we are also an R&D leader.

Therefore, our investment in research & development is one of the highest in our industry. In our research centres in Germany and France, 150 people are committed to working for a common future for our company and our customers. We are committed to offering our expertise wherever it is needed, anywhere in the world. This global presence ensures that our advances in fluid control technology are also global.

What we do in a nutshell

Manufacture of process equipment. One of the few manufacturers to provide solutions for the complete control loop.

Where we supply to

UK Ireland, Europe

Industries we supply to

Food and Beverage, Pharmaceutical Cosmetics Toiletries, Water and Wastewater

  • FLOWave | Oil dosing (English)

  • Feldbus Gateway Modul ME43: How to operate FLOWave (DE)

Show More

    Would you like further information about this article?

    Add your details below and we'll be in touch ASAP!


    Input this code: captcha

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Back to top button

    Join 25,000 process industry specialists and subscribe to:

    PII has a global network of suppliers ready to help...