Stop Guessing Which Hazard Study You Need

Take the Free Assessment Now →
Editorial ArchiveSolids Handling & ProcessingSolids Handling & Processing

Silo Protection Systems Prevent Powder Storage Silo Disasters

Nigel Allen, MD of Hycontrol

Listen to this article

The latest silo protection technology provides much more than a safety system to prevent over-filling and over-pressurisation.
According to Hycontrol’s MD Nigel Allen, many powder storage silos are disasters waiting to happen, putting lives at risk and posing serious threats to the environment.

Nigel Allen, MD of Hycontrol
By Nigel Allen, MD of Hycontrol

Level measurement specialists Hycontrol have been designing specialist silo protection systems for over 20 years and have extensive experience of the potential problems that exist on sites, especially in the quarrying, cement, bitumen, food, plastics and waste water industry sectors.

Our findings are worrying to say the least and the photos taken by our installation engineers speak for themselves”, says Nigel Allen

Companies just don’t seem to understand the consequences of poorly maintained protection systems. It’s quite frightening that operators accept pressure blow outs via the pressure relief valve (PRV), erroneously citing that ‘It’s OK – the PRV is doing its job’. This couldn’t be further from the truth – PRVs are there as a last resort. If the silo protection system is working correctly and is fitted with an automatic shut-off feature to prevent over-filling, the PRV should never be used. If a PRV blows then there’s an inherent problem with the system or the filling protocol and corrective action must be taken.” continues Allen.

powder storage silos, Silo Protection Systems
Material in and around a PRV is a tell-tale sign that there’s something wrong and a catastrophic blow-out is waiting to happen

The material blown out from the silos will almost certainly solidify over time and this will, at best, prevent the PRV from working correctly and, at worst, completely clog it up. Unfortunately many maintenance engineers just don’t realise the potential dangers that lurk beneath. They often think that simply cleaning off the material on and around the PRV is good enough. They don’t realise that if the PRV doesn’t lift next time an ‘event’ occurs, the over-pressure could easily rupture the silo or eject the filter housing from the top. On an ATEX rated silo the over-pressure could be sufficient to simulate an explosion and open the protective blast panels, resulting in costly loss of product and silo contents being left open to the elements”.

With regard to filter housings, Hycontrol engineers have witnessed another worrying practice at a number of sites where companies fit chains to prevent the housing being blown off the top of the silo, almost accepting the inevitable is going to happen.

Silo Protection Systems

What causes over-pressurisation problems?

Silo protection systems are designed to prevent the damaging and potentially dangerous consequences of silo over-filling or over-pressurisation when powdered material is being transferred pneumatically from road tankers to silos. Unfortunately, perched out on the top of silos, such protection systems are all too often ‘out of sight – out of mind’ – that is until a major problem occurs!

Problems during the filling process usually arise through an inherent problem with the silo protection system or with the air filtration system on top of the silo. Problems can also occur through tanker driver/operator error.

Delivery tankers are pressure-tested vessels typically capable of withstanding up to 2 bar (29 psi) pressure. Storage silos are designed to withstand the weight of material stored in them and can rupture at pressures as low as 1-2 psi above atmospheric pressure.The consequences of over-filling or over-pressurisation include:

  • Serious or fatal injury to workers and the public.
  • Catastrophic silo damage
  • Loss of material and production plus
  • Harmful environmental pollution
  • Damage to company reputation

A key issue with many silo protection systems is that without adequate ground level testing capabilities, operators don’t know if they will work when needed.

Working at height restrictions limit silo top inspections and maintenance, especially in adverse weather conditions. However, the main problem is what can engineers actually do when they are at the top of the silo? How do you physically test a relief valve or pressure transmitter unless you remove them?

Silo Protection Systems

Optimum solution

The only effective solution is to take an integrated approach to silo protection design whereby the PRV, pressure sensor and high level alarm can be tested at ground level, prior to each fill. Only when all these safety devices have passed the checks should the safety interlock allow the silo inlet valve to open and the delivery to commence.

As an added benefit, an effective protection system can serve as a powerful predictive maintenance diagnostic tool by recording critical near-miss events that occur during the filling process.

This information allows managers to carry out effective predictive maintenance by means of a logical step-by-step root cause analysis (RCA) process to understand why the problems are arising. For example, high pressure and PRV lift events may be due to filter problems, prompting questions such as:

  • Are the filters the correct size?
  • Is the filter cleaning regime fully operational?
  • Have the filter bags/cartridges been changed as per manufacturers’ recommendations?

In parallel the logs will also indicate if the tanker drivers are routinely over pressurising during the fill process.

In summary, the optimised silo protection system should incorporate:

  • Pressure sensor, hi-alarm level sensor and PRV testing (essential)
  • Simple ‘1’ button press to test all components
  • Silo filling auto shut-off control
  • Pneumatic cleaning of pressure sensor
  • Recording of the number of events on incidents of over-pressure (time /date stamp)
  • Recording of the number of events of PRV lift and opening (time /date stamp)
  • Recording of the number of events of high level probe activation (time /date stamp)
  • Filter ON / OFF output option to check filter status
  • Filter air supply monitoring alarm option

Conclusion

There is strong empirical evidence that many silos are ‘disasters waiting to happen’. The practical reality is that powder storage silos can split or rupture at pressures as low as 1 or 2 psi above atmospheric pressure. Malfunctioning filter housings can be ejected at similar pressures.

Cursory visual inspections of silo protection equipment is woefully inadequate. Therefore it is imperative that any installed safety system must be capable of providing reliable protection that can be easily verified by testing critical components before each and every delivery – without having to climb to the top of the silo.

This approach will provide total silo safety; protecting assets, the environment and most importantly site personnel and the public.

Show More

    Would you like further information about this article?

    Add your details below and we'll be in touch ASAP!


    Input this code: captcha

    Phil Black - PII Editor

    I'm the Editor here at Process Industry Informer, where I have worked for the past 17 years. Please feel free to join in with the conversation, or register for our weekly E-newsletter and bi-monthly magazine here: https://www.processindustryinformer.com/magazine-registration. I look forward to hearing from you!

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Back to top button

    Join 25,000 process industry specialists and subscribe to:

    PII has a global network of suppliers ready to help...