Using SF6 Gas in Medical Applications

Listen to this article

Medical applications utilising gases are wide and varied and include patient care, research and the manufacture of pharmaceutical products. Sulphur Hexafluoride (SF6) is a man-made gas comprising of one sulphur and six fluoride atoms. Key properties of the gas are that it is extremely chemically stable and has a relatively high density. Commonly used within the electrical industry as an insulating medium, the properties of the gas also make it highly suitable for use in ophthalmology.

Ophthalmology

Ophthalmology is the surgical or medical care of any conditions that affect the eye or its appendages. This can include; cataracts, genetic eye disorders, trauma or disease.

vitrectomy surgeryThe retina is a light-sensitive layer of tissue that lines the inner surface of the back of the eye. Metabolic tissue works to support the retina of the eyeball. However, this tissue can pull away, resulting in a macular hole or retinal detachment. Either one of these conditions can lead to distorted or impaired vision. Reparations can take place during a procedure called a vitrectomy.

Vitrectomies

During a vitrectomy, an ophthalmologist (medically trained eye specialists), will remove the vitreous humour, a clear gel-like substance that lies behind the iris. In doing so, they will gain access to the back of the eye, where they may repair the damaged retina.

At the end of the vitrectomy surgery, the ophthalmologist is required to fill the space left by the vitreous gel. This can be achieved by injecting a small amount of SF6 gas into the eye, in order to maintain the pressure required to allow the retina to remain in place and adequately heal.

Due to the high density of the SF6 gas the body is unable to absorb it for 3-4 weeks. In comparison, air takes only 1-3 weeks, which does not allow the eye sufficient time to repair.

Why is SF6 Gas Analysis Essential?

In order to validate their techniques, it is important that ophthalmologists analyse the composition of the SF6 gas prior to its use in surgery. In doing so higher precision, purity, traceability, accuracy and performance can be achieved.

Cambridge Sensotec is an established manufacturer of the Rapidox range of high precision gas analysers. The company collaborated with specialists in ophthalmology to develop a bespoke Rapidox SF6 6100 analyser, which is capable of analysing a minimal amount of SF6 gas.

As a privately owned company, staffed by highly skilled technologists, Cambridge Sensotec is perfectly placed to react to its customers specialised gas analysis requirements. Dynamic and flexible, the company are able to design and supply solutions to suit a variety of gas analysis applications.

Discover more about SF6 gas analysis at www.sf6.co.uk. Alternatively contact Cambridge Sensotec to discuss your application further. Contact us on: +44 (0)1480 462142 or email: sales@cambridge-sensotec.co.uk.

Show More

    Would you like further information about this article?

    Add your details below and we'll be in touch ASAP!


    Input this code: captcha

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Back to top button

    Join 25,000 process industry specialists and subscribe to:

    PII has a global network of suppliers ready to help...